The AVF7000 is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either
Flange or wafer connection. Standard configuration comes with local indication for flowrate and total flow as well as a 4-20mA output function output. The electronics are designed to filter out erroneous signals as well as noise due pipe vibration.
FEATURES
Simplified setup and diagnostic functions.
Auto. Temperature & Pressure compensation
4-20 mA and pulse outputs, user selectable.
a very wide selection of sizes.
Wide temperature range of up to 420 Deg. C.
Non-volatile memory for setup and calibration.
SPECIFICATION
Size:10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400,450,500mm
Material:
Stainless Steel 301 / 304 / 316
Accuracy:
Liquid:+/- 0.7% of reading
Gas & Steam:+/- 1.0% of reading
Process Connection:
Flange / Wafer
Flanges type:
JIS 10K / JIS 20K / JIS 40K
ANSI 150# / ANSI 300# / ANSI 600#
DIN PIN 10 / PN 16 / PN25 / PN 40
Temperature:
-40 ~ +280 Deg. C (Standard)
-40 ~ +420 Deg. C (Optional)
Protection:
IP 65
Explosion Proof, Exd IIC T6
Intrinsically Safe, E ex ia IIC T4
Local display:
4 lines LCD
4 digit flowrate
8 digit Totalizer
Communication:
RS485